| AAC Property | AAC Material | Laboratory | Test Report | Date |
|---|---|---|---|---|
| MSDS ACCOA AAC | AAC Blocks & Panels | MSDS | MSDS ACCOA AAC | mm/dd/yy |
| Dynamic Thermal Analysis | ACCOA AAC Blocks | Oak Ridge National Laboratory | Dynamic Thermal Analysis | 09/12/00 |
| Fire Resistance Rating - 4 Hr | ACCOA AAC Floor Panels 4" | UL Inc. | ANSI/UL 263-K909 | 08/22/01 |
| Fire Resistance Rating - 4 Hr | ACCOA AAC Floor Panels 8" | UL Inc. | ANSI/UL 263-K910 | 08/22/01 |
| Fire Resistance Rating - 3 Hr | ACCOA AAC Floor Panels 8" | UL Inc. | ANSI/UL 263-P931 | 08/22/01 |
| Fire Resistance Rating - 4 Hr | ACCOA AAC Floor Panels 4" | UL Inc. | ANSI/UL 263-P932 | 08/22/01 |
| Fire Resistance Rating - 4 Hr | ACCOA AAC Floor Panels 8" | UL Inc. | ANSI/UL 263-P933 | 08/22/01 |
| Fire Resistance Rating - 4 Hr | ACCOA AAC Blocks 8" | UL Inc. | ANSI/UL 263-U916 | 08/22/01 |
| Fire Resistance Rating - 4 Hr | ACCOA AAC Blocks 6" | UL Inc. | ANSI/UL 263-U917 | 08/22/01 |
| Fire Resistance Rating - 4 Hr | ACCOA AAC Blocks 8" | UL Inc. | ANSI/UL 263-U918 | 08/22/01 |
| Fire Resistance Rating - 4 Hr | ACCOA AAC Blocks 6" | UL Inc. | ANSI/UL 263-U919 | 08/22/01 |
| Fire Resistance Rating - 4 Hr | ACCOA AAC Blocks 6" | UL Inc. | ANSI/UL 263-U920 | 08/22/01 |
| Fire Resistance Rating - 4 Hr | ACCOA AAC Blocks 6" | UL Inc. | ANSI/UL 263-U921 | 08/22/01 |
| Fire Resistance Rating - 4 Hr | ACCOA AAC Blocks 4" | UL Inc. | ANSI/UL 263-X901 | 08/22/01 |
| Sound Transmission Loss | 8.0” AAC Block Wall | Riverbank Acoustical Laboratories | RAL-TL99-123 | 07/29/99 |
| Sound Transmission Loss | 8.0” AAC Block Wall with ½” Gypsum Board on One Site | Riverbank Acoustical Laboratories | RAL-TL99-124 | 07/29/99 |
| Sound Transmission Loss | 8.0” AAC Block Wall with Simulated Plaster Interior Finish | Riverbank Acoustical Laboratories | RAL-TL99-125 | 07/30/99 |
| Sound Transmission Loss | 8.0” AAC Slab Floor | Riverbank Acoustical Laboratories | RAL-TL99-113 | 07/16/99 |
| Sound Transmission Loss | 8.0” AAC Slab Floor with Carpet & Padding & Simulated Plaster Ceiling | Riverbank Acoustical Laboratories | RAL-TL99-115 | 07/20/99 |
| Sound Transmission Loss | 8.0” AAC Slab Floor with a Simulated Plaster Ceiling | Riverbank Acoustical Laboratories | RAL-TL99-116 | 07/20/99 |
| Impact Sound Transmission Loss | 8.0” AAC Slab Floor | Riverbank Acoustical Laboratories | RAL-IN99-11 | 07/16/99 |
| Impact Sound Transmission Loss | 8.0” AAC Slab Floor with Carpet & Padding & Simulated Plaster Ceiling | Riverbank Acoustical Laboratories | RAL-IN99-12 | 07/20/99 |
| Impact Sound Transmission Loss | 8.0” AAC Slab Floor with a Simulated Plaster Ceiling | Riverbank Acoustical Laboratories | RAL-IN99-13 | 07/20/99 |
| Structural Tests on AAC Reinforced Panels manufactured by ACCOA | ACCOA AAC Reinforced Panels | CTL | CTL199006, CTL199007 CTL199008, CTL199012 | July 1999 |
| Material Tests of ACCOA AAC | Masonry Blocks and Assemblies | CTL | CTL 183035 | 08/19/99 |
| Pull-Out & Shear Tests of Fasteners for AAC | ACCOA AAC Blocks & Panels | CTL | CTL 210515 | June 2000 |
| Mines: Ventilation Stopping | ACCOA AAC Blocks | Mine Safety & Health Administration | MSHA PAR 89045 | 08/21/03 |