Wall elements comprise steel reinforced AAC in a standard number of widths, depths, and lengths to suit the layout and structural design of the project. Each wall element is provided with a profile along its length to ensure a strong, tight fit. The combination of AAC and steel reinforcement cages enables large spans up to 20'-0" (nominal) to be achieved whilst retaining all the characteristics of AAC. The thickness of the wall element is typically 8.0" and standard width 24.0".
ASTM C-1452: Standard Specification for Reinforced Autoclaved Aerated Concrete Elements
AAC-4.0/600 : COMPRESSIVE STRENGTH = MIN. 4 N/mm2 or MIN. 580 psi
NOMINAL DRY DENSITY = 600 kg/m3 or 37 lb/ft3
The design weight of the PAAC-4/600 equals 45 pcf or 30 psf for the thickness 8.0"
The transport weight of the PAAC-4/600 equals 50 pcf
REPAIR & PATCH MORTAR: BAG = 55 lbs
FULL TRUCK LOAD = APPROXIMATELY 45,000 lbs
SIZES & AVAILABILITY SUBJECT TO CHANGES WITHOUT NOTICE
MAX PANEL LENGTH = 20'-0" , MAX PANEL WIDTH = 24" , MIN PANEL WIDTH = 12"
PANEL LENGTH & PANEL WIDTH per 0.5" INCREMENTS
POSSIBLE PANEL THICKNESS = 4.0", 6.0", 8.0", 9.5" AND 12.0"
POSSIBLE WALL PANEL PROFILES: ACCOA AAC Panel Profiles
P+P = PLAIN + PLAIN
T+G = TONGUE + GROOVE
T+P = TONGUE + PLAIN
P+G = PLAIN + GROOVE
R+R = ROUND + ROUND
R+P = ROUND + PLAIN
POSSIBLE STEEL CAGE COVERS: 27 mm, 40 mm or 53 mm
DIAMETER LONGITUDINAL BARS: 6 mm or 8 mm , DIAMETER CROSS BARS: 6 mm
MAX. # OF BARS: TOP and/or BOTTOM = 9 , MIN. # OF BARS: TOP and/or BOTTOM = 4